Hasting
Loop Impedance Meter MZC-305
Earth Resistance Meter MRU-20
Thermal Imagers KT-160/160A
HD Thermal Resolution KT-384
Earth Resistance Meter MRU-200
Wireless Inspection Camera
Insulation Resistance Meter MIC-5000
Portable Appliance Tester PAT-805
Micro Ohm Meter MMR-620/630
POWER QUALITY ANALYZER PQM-701
Digital Clamp-On Multimeter CMP-1006
WIRE TRACER LKZ-700
WIRE TRACER LKZ-710
Data Logging Light Meter LXP-1
Ohmstik Plus
Ampstik Plus
Radio Voltstik
EK 60 UNV-L
EK 60/22-L
EK 35/4 L & ES 20
Taekwang
PITE 3915 Battery Tester
FTU P100 PNC
LBS Pole PNC
SAG Mini gateway
PAC-E500 Under Frequency Relay

PNC

Numerical Protection & Digital Power Meter

DPM B100
Complite with RMS of 3-phase voltages and currents, power, energy, power factor, and frequency measurements, the DPM-B Series is variety of flexible configurations including IEC standard.
It offers outstanding quality, veratility, and functionality in a low-cost, ultra-compact meter....more detail

 
DPM B150
DPM-B150 Series is going to control and monitor circuit breaker efficiently as well as integrates analog and digital measurement point in conrmity superior circuit drawing, elegant and high trust. The DPM-B Series is simple to use, and offers a big, bright LCD display for superior readability in adverse lighting conditions....more detail  
   
PAC E100
PAC-E100, Over Current & Earth Fault Relay is a microprocessor-based numerical protection relay designed for the management and protection of a distribution feeder. PAC-E100 has the protection elements of Over Current (OCR), Ground Over Current (OCGR), Thermal Overload, Under Current, and Negative Phase Sequence Over Current. It has 4 standard IEC TC curves (Normal Inverse, Very Inverse, Extremely Inverse, Long-time Inverse), 7 standard ANSI TC curves and 2 KEPCO’s induction type TC curves (KEPCO Normal Inverse, KEPCO Very Inverse). Also it provides the measurements of 3 phase currents, Sequence Current, THD (Total Harmonic Distortion), and frequency, and control functions for a circuit breaker....more detail  
   
PAC E150
PAC-E150, Over Current & Earth Fault Relay is a microprocessor-based numerical protection relay designed for the management and protection of a distribution feeder. PAC-E150 has the protection elements of Over Current (OCR), Sensitive Ground Over Current (SOCGR), Thermal Overload, Under Current, and Negative Phase Sequence Over Current. It has 4 standard IEC TC curves (Normal Inverse, Very Inverse, Extremely Inverse, Long-time Inverse), 7 standard ANSI TC curves and 2 KEPCO’s induction type TC curves (KEPCO Normal Inverse, KEPCO Very Inverse). Also it provides the measurements of 3 phase currents, Sequence Current, THD (Total Harmonic Distortion), and frequency, and control functions for a circuit breaker....more detail  
   
PAC E500
PAC-E500, Over Current & Earth Fault Relay is a microprocessor-based numerical protection relay designed for the management and protection of a distribution feeder.
PAC-E500 has the protection elements of Over Voltage (OVR), Under Voltage (UVR), Ground Over Voltage (OVGR), Negative Phase Sequence Over Voltage and Under Frequency.
It uses Normal Inverse of TC curves (1 OVR and UVR, 2 OVGR). Also it provides the measurements of Lineto- Line voltage, 3 phase currents and voltages, Sequence Voltage, THD (Total Harmonic Distortion), frequency, and PT fuse fail monitor, and control functions for a circuit breaker....more detail  
 SELAMAT DATANG DI WEBSITE AURASINARINDO ABADI